Sign In | Join Free | My benadorassociates.com
China SHEN ZHEN YIERYI Technology Co., Ltd logo
SHEN ZHEN YIERYI Technology Co., Ltd
SHEN ZHEN YIERYI Technology Co., Ltd YIERYI,Your family health guardian!
Verified Supplier

9 Years

Home > Digital PH Meter >

PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer

SHEN ZHEN YIERYI Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer

Model Number : PHS-3C

Brand Name : YIERYI

Place of Origin : Guangdong, China

MOQ : 2

Price : AED 145.76-152.27

PH range : 0.00-14.00PH

Temperature range : 0-100℃

PH resolution : 0.01PH

Temperature resolution : 0.1℃

PH accuracy : ±0.02PH

Temperature accuracy : ±0.5℃

PH display : 4-digital LED

Temperature display : 3-digital LED

Temperature compensation : 0℃-50℃

Working temperature : 0℃-50℃

Calibration points : 2 points

Calibration type : Automatic buffer recognition

Power supply : On the label

Model number : PHS-3C

Product type : Water Quality Analyzer

Contact Now

PHS-3C Auto Calibration Acidity Meter Water Quality Analyzer
Product Specifications
Specification Details
Customized Support OEM
Place of Origin China, Guangdong
Brand Name YIERYI
Model Number PHS-3C
Product Name PH Meter
PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer
Technical Specifications
  • Range: PH: 0.00-14.00PH, Temperature: 0-100℃
  • Resolution: PH: 0.01PH, Temperature: 0.1℃
  • Accuracy: PH: ±0.02PH, Temperature: ±0.5℃
  • Display: PH: 4-digital LED, Temperature: 3-digital LED
  • Automatic temperature compensation: 0℃-50℃
  • Power supply: As specified on the label
  • Working temperature: 0℃-50℃
  • Calibration: 2 points with automatic buffer recognition
PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer
pH Calibration Procedure
  1. Pour a small quantity of pH 6.86, pH 4.00, and pH 9.18 solution into clean beakers
  2. For particularly accurate calibration, use two beakers for each buffer solution - one for rinsing the electrode and one for calibration to minimize contamination risks
  3. Switch on the instrument
  4. Immerse the electrode in pH 6.86 buffer solution and gently shake until the reading stabilizes
  5. Press the "CAL" button until the calibration indicator lights up, then press "PH7" until the display shows "6.86". Rinse the electrode with distilled water
  6. Immerse the electrode in pH 4.00 buffer solution and gently shake until the reading stabilizes
  7. Press the "CAL" button until the calibration indicator lights up, then press "PH4" until the display shows "4.00". Rinse the electrode with distilled water
  8. Immerse the electrode in pH 9.18 buffer solution and wait for the reading to stabilize until the display shows exactly 9.18
  9. The calibration of the instrument's pH range is now complete
Packing & Delivery
PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer
Original box gift box packaging included

Product Tags:

Auto Calibration Digital PH Meter

      

0-14.00PH Range Water Quality Analyzer

      

2 Points Calibration Acidity Meter

      
Quality PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer for sale

PHS-3C Auto Calibration Digital PH Meter with 0-14.00PH Range and 2 Points Calibration Water Quality Analyzer Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: SHEN ZHEN YIERYI Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)